5-9 September 2016
Prague Congress Centre
Europe/Prague timezone

P2.048 Neutronics analysis for the ITER tritium and deposit monitor diagnostics

6 Sep 2016, 14:20
1h 40m
Foyer 2A (2nd floor), 3A (3rd floor) (Prague Congress Centre)

Foyer 2A (2nd floor), 3A (3rd floor)

Prague Congress Centre

5. května 65, Prague, Czech Republic
Board: 48
Poster D. Diagnostics, Data Acquisition and Remote Participation P2 Poster session

Speaker

Arkady Serikov (Institute for Neutron Physics and Reactor Technology)

Description

This paper presents new results of neutronics analysis performed in support for the design development of the Tritium and Deposit Monitor (TDM) to be installed inside the ITER Equatorial Port Plug (EPP) #17. This monitor is a laser based diagnostics to provide information about the tritium content in the deposited layer on the inner baffle of the ITER divertor. Neutronics analysis is performed with the local MCNP models of EPP#17 which comprises two adjacent diagnostics:  TDM and Core-Imaging X-ray Spectrometer (CIXS). The MCNP 3D models were converted from the corresponding CAD models. Critical neutronics issues related to radiation streaming, nuclear heating and activation are discussed and found shielding design solutions are presented in this paper. It was proposed to increase the length of one segment between two particular mirrors in the labyrinth optical mirror system to prevent direct neutron streaming from the plasma to the optical box in Port Interspace (PI), where maintenance is planned ~12 days after shutdown. Shield block made of boron carbide behind the optical box was added. To provide the possibility of personnel access to the PI area, Shut-Down Dose Rate (SDDR) has been calculated with the results presented as map distributions and estimates in spherical detectors. Using the Rigorous 2-Step mesh-based (R2Smesh) method of SDDR calculations which combines the FISPACT activation and MCNP transport allowed us to distinguish different decay gamma sources in forming the SDDR. The SDDR results are presented for two variants of the EPP17-CIXS models, with and without the monitor. Therefore the contribution to SDDR from the monitor was deduced. This work provides only the relative values of SDDR. The absolute values will be obtained after the finalizing of the designing work for all the EPP17 diagnostics. This is a forthcoming task of EPP17 diagnostics integration into the ITER-global C-lite MCNP model.

Co-authors

Arkady Serikov (Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany) Christophe Penot (Port Plugs & Diagnostics Integration Division, ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex, , France) David Anthoine (Port Plugs & Diagnostics Integration Division, ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex, , France) Luciano Bertalot (Port Plugs & Diagnostics Integration Division, ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex, , France) Ulrich Fischer (Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany)

Presentation Materials

There are no materials yet.